After a routine inspection, Xu Chuan entered the exam room and received his test paper.
The instruments on the desk gave him a rough idea of what the exam would cover. He picked up the white paper and looked it over. Sure enough, it was much as he had expected.
"National High School Physics Competition experimental examination questions."
Question 1: Measure the equivalent circuit parameters of a coaxial cable.
Introduction: In ordinary circuits, when the frequency of a current or voltage signal is low, the electrical signal is transmitted essentially along the wire loop.
If the signal frequency reaches several hundred kHz or higher, making it a radio-frequency signal, ordinary wires emit electromagnetic waves into space like antennas and therefore cannot serve as effective channels for transmitting electrical signals.
To transmit radio-frequency signals, transmission lines with special structures, such as coaxial cables, are commonly used. In use, one end is connected to a signal source and the other to a load.
This experiment uses different methods to measure several characteristic parameters of the same uniform coaxial cable. Ignore losses in the coaxial cable. Do not evaluate uncertainty for any results.
Experimental apparatus: a 5.00-meter coaxial cable to be tested; a signal source with internal resistance R0, capable of producing signals of different frequencies and waveforms; two AC voltmeters capable of measuring the root-mean-square value of AC voltage; a dual-channel digital oscilloscope; resistors; wires; and so on.
Experimental tasks:
A. Measure the equivalent capacitance and inductance of the coaxial cable using a low-frequency sinusoidal signal (8 points).
When the frequency of the sinusoidal signal is very low and its wavelength is much greater than the length of the coaxial cable under test, the cable can be approximated by the equivalent circuit shown in Figure 2. C and L are respectively the equivalent capacitance and equivalent inductance of the entire cable under low-frequency conditions, and satisfy the following relation:
1/2πC >> 2πL
B. Measure the characteristic impedance, wave speed, and equivalent capacitance and inductance per unit length of the coaxial cable using a pulsed square-wave signal (32 points).
(1) When the signal frequency is relatively high and the wavelength is close to or much shorter than the length of the coaxial cable, the current flowing through the central conductor and the voltage between the inner and outer conductors vary along the cable in a wave-like manner. If the coaxial cable is divided into several short segments, so that the length of each segment Ax
(2) Characteristic impedance is a fundamental parameter of a coaxial cable. If two coaxial cables with characteristic impedances of z. and Z respectively are connected, as shown in Figure 4(a), transmission and reflection occur at the interface connecting them. Let the voltage of the input signal arriving at the interface through the coaxial cable with characteristic impedance Z. be V
One question, two sets of experiments, three tasks.
Xu Chuan spent a few minutes reading through the entire question.
Compared with the written exam, the experimental question really offered little that was new. It was all high school physics: electric currents, optics, sound waves, magnetic fields, and the like.
Compared with cutting-edge physics, high school physics did not leave many experiments for students to perform.
Even though students who could take part in the competition knew far more than ordinary high school students, they had yet to enter university or society. Mid- to high-end instruments and dangerous experiments, such as those involving high-voltage currents, were unlikely to be made available to them.
This National Finals tested equivalent circuits, equivalent inductance, and pulse signals.
As physics experiments went, it was fairly ordinary. The question was not particularly difficult, but the experimental procedures were quite complicated and required the students taking the exam to be very careful.
After all, more steps meant more opportunities to lose points.
Even Xu Chuan conscientiously followed the standard procedure as he performed the experiment.
"Bang!"
Suddenly, a sound like something falling to the floor rang out in the exam room. The startled students looked up, interrupting their work.
Xu Chuan was no exception. He turned toward the sound and saw that a student had knocked a meter off the desk.
The black-and-white meter rolled twice across the floor. One corner broke, sending two tiny shards of glass flying.
The examinee at the desk where the meter had been, probably taking part in the National Finals for the first time, stood there trembling after dropping the instrument with a shake of his hand. His face was pale, and he had no idea what to do.
The noise drew the attention of an invigilator, who walked straight over, picked up the broken meter, and examined it.
Standing nearby, the trembling examinee saw the teacher inspecting the instrument and felt he had caused trouble. Under the enormous pressure of the National Finals, his vision went black, his body went limp, and he actually fainted.
Well, now it was the invigilator's turn to tremble.
Forgetting about the broken meter, he hurried over and helped the unconscious examinee up.
"Hey!"
"Student, student."
"Wake up, wake up."
With someone unconscious, the invigilators immediately grew anxious. Two or three of them rushed over to administer first aid to the student, while the others continued maintaining order in the exam room.
"Where's the medical team? A student has fainted in exam room three. Hurry over!"
The exam room descended into chaos. As the invigilators administered first aid by pressing the student's philtrum and temples, they called for the medical staff outside the room.
The medical staff received the call for help and soon arrived, carrying the unconscious student out.
Once the unconscious student had been taken away, the invigilators returned to the exam room and resumed supervising the exam. But after that interruption, the atmosphere throughout the room had changed.
Some people grew even more nervous; others' hands trembled as they held their power supplies.
Xu Chuan shook his head and continued his experiment.
In fact, whether it was the math or Physics Olympiad, people fainted in the exam room every year.
This was especially true of students who had made it to the National Finals for the first time and were taking the national exam. Under enormous pressure, the slightest disturbance could snap the taut nerve in their minds.
Compared with the chemistry competition, however, math and physics were much better. At least there were no external dangers.
The math competition had no experimental questions, and the experimental questions in the Physics Olympiad were basically free of danger.
The chemistry competition was different. Its experimental questions sometimes involved all kinds of hazardous substances.
For example, chemical substances such as paraformaldehyde, glycine, phenylenediamine, and phenol.
These were common and frequently used materials in chemistry competitions, but they were all toxic. Some were even highly toxic and could easily enter the human body through the skin or the air, causing harm.
Anyone in chemistry competitions who regularly worked in a chemistry lab should know that quite a few students suffered poisoning because of chemistry competitions every year.
The thing chemistry competition teachers said most often when coaching students was to remind them to pay attention to safety.
So taking part in competitions was actually dangerous too.