Skip to main content
  • Home
  • Library
  • Read
    • Popular
    • Charts
    • Browse
    • Categories
    • Wikis
    • Glossary
  • Request
  • Activity
  • Leaderboard
  • Help
Our Apps
  • DaoSearch
  • Narratorr
Social
  • Discord
  • Patreon
I Can Extract Side Effects
Chapter 537

Artificial Blood Vessel AV Fistula, the Lifeline of Dialysis

2,673 words 9 min read 0 views 3mo ago Source ​
Skip to the end of the chapter
Prev
Next

No wonder Fischer was unimpressed by Three Purities's large-diameter Artificial Blood Vessel.

Because Maquet is one of the world's largest suppliers of operating room and ICU medical equipment, founded in 1838, it has a history of nearly 200 years.

Since manufacturing the world's first electric operating table 90 years ago, it has become the absolute king in the fields of ventilators, ECMO equipment (heart-lung machines), and Artificial Blood Vessel through continuous acquisitions and development.

Whether it's ECMO, ventilators, or Artificial Blood Vessel, Maquet holds a monopoly, possessing a 70% global market share.

As a long-established giant in surgical instruments, having weathered 200 years of trials and tribulations, it naturally did not take Three Purities, a rising star, seriously.

Unlike Terumo, Maquet possessed the confidence and pride of the Germany, firmly believing that the field of Artificial Blood Vessel, which he had developed single-handedly, would never be surpassed by any newcomer.

Sakura Country companies, having been hampered by domestic approval processes for a long time and relegated to the second tier, naturally lacked confidence and were hesitant before even starting.

Of course, this is mainly because the media only reported on aortic replacement surgery, which mainly uses large-diameter Artificial Blood Vessel with a diameter greater than 10 millimeters.

The technology for large blood vessels is already mature and has been widely commercialized, so it is theoretically not difficult to implement.

The main reason why domestic Artificial Blood Vessel have been unable to make breakthroughs is that upstream polyester materials need to be imported. There are no self-developed materials, so we have been held back by the bottleneck.

Moreover, polyester material also has a problem: it can easily clog blood vessels after prolonged use.

Arteries are a bit better because they are large enough, and patients often take Anticoagulant Drug for a long time before blockages occur. They are not visible at first and require long-term testing within the patient's body to ensure that no problems will occur.

In comparison, medium-diameter Artificial Blood Vessel of 6-10 mm are more difficult to manufacture. These vessels are generally used to replace veins, where blood flow is slower, blood cells and impurities accumulate, leading to thickening of the intima and making thrombosis more likely.

If Artificial Blood Vessel becomes blocked by a blood clot, it means the transplant has failed, and in severe cases, it can be even more dangerous than before the transplant.

Therefore, the choice of materials for Artificial Blood Vessel is crucial, and the application of anticoagulant coatings is also very important.

That's why leading companies Maquet can build high technological barriers and form a monopoly.

As for Small-bore Artificial Blood Vessel of less than 6 millimeters, this remains an international challenge and urgently needs to be addressed.

It was through continuous technological improvements that Maquet was able to secure its leading position.

However, it has not been able to develop Artificial Blood Vessel smaller than 6 millimeters.

Therefore, as long as Three Purities does not make a breakthrough in this area, Maquet feels that it is not a problem and it is difficult to shake his dominant position.

Having figured this out, Fischer was no longer worried and instead turned his attention to the new factory's production capacity.

Thinking about anything else is useless; the most important thing is to restore supply as soon as possible.

******

Kun City, First People's Hospital, Blood Purification Room.

At 5 p. m., just as dialysis patients were finishing up, medical staff were busy organizing data and the machines.

Suddenly, hurried footsteps came from outside the door, and an elderly man in his sixties with gray hair and beard hurriedly walked in, supported by his family.

Nurse Xiao Li looked up and was immediately surprised. It turned out to be an old acquaintance, Grandpa Old Man Liu.

Old Man Liu has been a regular at the Dialysis Room since last year, and Nurse Li knows him very well. She smiled and asked, "Old Man Liu, what's up? Didn't you just finish dialysis this morning? Why are you back again?"

Before Old Man Liu could speak, his family members next to him started shouting anxiously.

"My dad came home after dialysis at noon and was fine, but about an hour ago he realized something was wrong. His AV Fistula seemed to have stopped. We rushed him to the hospital. What could have happened?"

As soon as she finished speaking, Nurse Li's expression turned serious, and she quickly came over to check the fistula on Old Man Liu's arm.

Arteriovenous fistula (AVF) is a common and important access route for maintenance Hemodialysis in patients with chronic renal failure, and is a lifeline for patients to survive.

For patients with poor vascular conditions, surgery can be used to anastomose the arteries and veins of the upper limb. The artery near the wrist in the forearm is sutured together with the adjacent vein, so that arterial blood flows in the anastomosed vein, forming an arteriovenous fistula.

This ensures a sufficient blood supply for Hemodialysis treatment, reduces the chance of infection, does not affect daily life, and provides adequate support for dialysis treatment.

Because arterialization of veins produces tremors and murmurs, patients and medical staff can directly feel the blood flow and monitor their condition.

Right now, even to the naked eye, this fistula has completely lost all vitality, showing no signs of movement, silent as a dead object.

Nurse Li's expression changed, and she immediately called the on-duty doctor.

The on-duty doctor arrived quickly and, after understanding the situation, immediately made a judgment.

"It's probably an AV Fistula blockage caused by impotence."

Upon hearing this, the patient's family members' faces immediately fell, and they began to complain incessantly.

"Traffic jam again? What's going on?"

"My dad is almost 70 years old. He started dialysis last year and has had four surgeries in the past six months. He has also had several blockages for AV Fistula. This is the fourth time."

"Is your technology even up to par?"

The on-duty doctor comforted them, saying, "I understand how you feel. Don't worry. The main problem is that the elderly are old and weak, and their blood vessels are already in poor condition, making them prone to blockages. Besides, the punctures required for dialysis are very damaging to the blood vessels themselves, so there's nothing we can do about it."

"Let's focus on the illness first and solve the problem, okay?"

Upon hearing this, the family members' expressions softened somewhat. Although they were anxious, they didn't say anything more.

The on-duty doctor got up and made a phone call, "Director, there's an emergency I need to report to you. Okay, activate the emergency plan for impotence and blockage AV Fistula, contact the thrombolysis team and the access physician, right? I understand."

After hanging up the phone, he picked up a Portable Color Ultrasound, went to the patient's bedside, and used ultrasound to assess the AV Fistula.

When the image of the AV Fistula angioplasty appeared on the screen, everything was clearly visible and easy to understand.

It turns out that a small 2-centimeter-long blood clot appeared 1.5 centimeters away from the opening of the AV Fistula, near the heart, causing the blood flow to stop near the heart.

"Phew~" The on-duty doctor breathed a sigh of relief. Finding the blockage made things easier; as long as the blood clot was cleared in the shortest possible time, the problem could be solved.

Five minutes later, the head of the urology department and the thrombolysis team arrived together. After assessing the situation, they proposed a treatment plan.

"The thrombus has formed relatively recently, so we can try thrombolysis first."

At this moment, the head nurse arrived and immediately assisted in performing the puncture, administering Urokinase intravenously for thrombolysis.

Under ultrasound guidance, the needle tip passes through the AV Fistula blood vessel and approaches the atrophy site.

At a command, 100,000 units of Urokinase were sent directly into the arterial blood, rushing rapidly towards the thrombus site.

"Hopefully, the action of Urokinase, combined with the impact and massage of arterial blood flow, can break open the blood clot and create a miracle."

"This is the path to life, and we must persevere to help the patient get through this difficult time."

The medical staff looked tense, some staring at the ultrasound screen, others at the AV Fistula angioplasty, all intently praying and waiting for a miracle to happen.

However, as time ticked by, and after a long hour, all 100,000 units of Urokinase had been infused, the AV Fistula blood vessels remained completely still.

"No thrill upon palpation, no murmurs upon auscultation, and no blood flow upon ultrasound assessment."

"Based on past experience, a blood clot that can be cleared should show some signs of healing at this point, but it hasn't."

After examining him again, the head of urology looked disappointed and shook his head.

The already tense atmosphere in the hemodialysis room was immediately shrouded in a sense of disappointment.

The doctors and nurses looked at each other, unsure of what to say.

The director looked around and said in a deep voice, "Don't panic. Let's continue to discuss the next treatment plan. Considering that this is the fourth time the patient has AV Fistula blockage, we can basically rule out surgical anastomosis as the cause. It should be due to poor vascular conditions and abnormal vascular endothelial function leading to hypercoagulability, which causes repeated AV Fistula blockage."

"It seems that given the patient's physical condition, it is unlikely that he can establish his own AV Fistula. Even if he undergoes surgery again, there is a high probability that blood clots will continue to form, blocking the blood vessels in the AV Fistula. This is not a long-term solution."

"Then we can only suggest that the patient change the treatment plan."

The doctors who participated in the consultation nodded in agreement and began a lively discussion.

"A stable and reliable vascular access is the basic guarantee for successful Hemodialysis."

"Generally speaking, this condition is considered to be a semi-permanent cannula in the internal jugular vein, or AV Fistula Artificial Blood Vessel."

"Semi-permanent cannulation of the internal jugular vein is simple and easy to perform, and is a good way to reconstruct Hemodialysis access."

"This won't work. The patient needs long-term dialysis. The semi-permanent cannulas for the internal jugular vein are made of polyester and can only be used for a short period of time. If they are used for too long, they are prone to functional impairment, which will be difficult to resolve."

"Artificial Blood Vessel AV Fistula are no good. They are all older generation products with various clinical problems, short patency time, easy to cause complications, and high infection rate. Moreover, they are very expensive. Patients already need long-term dialysis, which is a heavy financial burden and not a good solution."

"Autologous vein transplantation is a good option for patients. It has good compatibility, eliminates concerns about antigens, avoids high costs for consumables, has fewer complications, and results in good postoperative recovery. Although the surgery is a bit complicated, it is the best choice for patients."

"But when I examined the patient's lower limb veins, the blood vessels were much thinner than those of ordinary people, so I'm afraid I can't perform the AV Fistula procedure."

"Oh, what should we do? It seems there's no perfect solution."

"There is a way to achieve the best of both worlds," the head of urology said thoughtfully, an idea suddenly popping into his mind.

"What do you think about using Three Purities's Artificial Blood Vessel for transplantation?"

"They can all be used in the aorta, so the diameter is definitely thick enough, and the elasticity is also very good. They are all biological materials, so the compatibility is good, and there is no need to worry about antigenicity."

"Because it's a clinical trial, it's free to use. I've seen patients who have undergone aortic replacement surgery, and their postoperative recovery is quite good. So far, there haven't been any negative reviews."

The doctors' eyes lit up with surprise, and they immediately began to think about it, offering their opinions one after another.

"It sounds like a good idea. I just don't know how durable it is. Patients need to get a needle inserted every week for dialysis. I wonder if this Artificial Blood Vessel can last a long time?"

"Don't worry about that. It's better than the patient's own blood vessels. The patient's own veins are so fragile."

"I haven't used it for a long time, so I don't know how well it works. I'm worried that it might cause blood clots again after a few weeks of use."

"It shouldn't be a problem. It's thicker than a vein and has enough elasticity. If a blood clot does form, interventional treatment can be used."

"That makes sense, that method is indeed feasible."

The head of urology glanced at the clock on the wall; two hours had passed since it was time to leave work.

Footsteps could be heard from outside from time to time; those were the family members waiting anxiously outside the door, pacing back and forth, awaiting the final result.

He coughed lightly and immediately made a decision.

"That's settled then. We'll use Artificial Blood Vessel from Three Purities to perform the AV Fistula surgery."

"I'll go explain to the family, and you should start preparing for the surgery as soon as possible."

The family members were so anxious that they were at their wits' end, and they immediately agreed to the surgery plan as if it were the last straw.

The head of urology then called Three Purities's pharmaceutical representative to inquire about the model of the Artificial Blood Vessel.

"Is Three Purities 6-8 mm diameter Artificial Blood Vessel suitable for AV Fistula surgery?"

Since AV Fistula is usually treated by transplanting veins, the diameter of the blood vessel cannot be too thick or too thin; 6-8 millimeters is ideal.

"We can provide any diameter, including those larger than 6 millimeters. But if it's for treating arteriovenous AV Fistula, we have an even more suitable vessel, which is a small-diameter vessel of 5 millimeters."

"Rest assured, because it is elastic enough and has been strengthened in toughness, it can be used for needle punctures in long-term dialysis, and it also has a self-healing function."

Upon hearing this, the head of urology was immediately astonished. "What? You even have 5-millimeter-diameter blood vessels? That's incredibly impressive! This is an international problem, and you've solved it all?"

Then he was overjoyed. "That's even better! Quickly send over a 5-millimeter Artificial Blood Vessel."

The veins in the upper arm are naturally quite thin. If they are too thick, they will be difficult to embed themselves in the subcutaneous tissue. So, while preserving the same function, the thinner the vein, the better.

"Okay, I'll be there soon."

Half an hour later, the Artificial Blood Vessel arrived as if by chance.

The surgery went smoothly, and everyone worked against the clock to clear the blood clot as quickly as possible.

First, the thrombosed, AV Fistula blood vessel is removed, and an artificial vein of the same length is transplanted. Then, it is connected to the artery to artificially form a direct arteriovenous connection in the body.

The purpose of the surgery is to increase blood flow in superficial veins, making puncture easier and facilitating Hemodialysis.

Although a 5mm blood vessel is considered small in diameter, it is still larger than a 2.5mm superficial vein. After the transplant is completed, a noticeable bulge appears on the patient's arm.

After the last stitch was completed, the surgeon first released the venous clamp, then the arterial clamp, to completely restore blood flow.

Instantly, everyone's eyes turned to that direction.

A finger rested on the bulging vein, pausing for three seconds.

"I could feel a distinct vasoconstriction, and blood flow has finally been restored."

"As expected, the operation was successfully completed."

"Look, the color Doppler ultrasound has detected blood flow too."

And so, the path of life opened once more!

Everyone smiled knowingly and applauded at the same time.

End of Chapter
Prev
NovelSummaries
Next

Explore the wiki

Three Purities

Comments

No comments yet.
AboutStatsAPIChangelogStatusContactPrivacyTermsDMCA
© 2026 RandomTranslator·v3.26·RSS