Everyone else's work is organized by the construction unit, but this one is special. This fourth point must be handled according to general and key control items. All materials related to structure, safety, environmental protection, energy conservation, and main functions must be inspected and verified according to regulations. This is, after all, related information on witness inspection and quality management. For all sub-projects involving structural safety, environmental protection, energy conservation, and main functions, based on the overall sample, let's first look at the division of building construction quality acceptance units into four levels: according to the quantity of work, floor, construction section, according to the second sub-item of these four contents, according to the type of work and materials... The types of construction technology and equipment, classified according to professional nature, are based on the 2017 session. Let's first look at the management of the second unit. The construction unit should complete the review of the construction unit for the project inspection batch. For projects and cleanliness issues not covered by the specifications, the construction unit should organize the supervision and construction units to negotiate and determine them. We just mentioned the river, which was also determined by the construction unit organizing relevant units. Similarly, for any sub-projects and cleanliness issues not covered by the specifications, the construction unit should organize the supervision and construction units to write them down. Now we Let's take a look at the key points to grasp, like this pink elephant. Who participates? It must be the quality inspector. Also, the professional supervising engineer. Then its project manager and project technical manager participate. These two organizations often focus on the acceptance of this sub-project. It's usually organized by the chief supervisor or the project manager of the construction unit, the project manager of the construction unit, and the project technical manager. However, the project manager of the surveying and design unit and the technical quality department of the construction unit are responsible and must participate in the basic foundation work. The project manager of the design unit and the technical quality department of the construction unit are responsible and must also participate in the main energy-saving project. Last year's exam included a summary of the foundation and the project manager of the construction unit, the project manager and project technical manager of the construction unit, the project manager of the surveying and design unit, and the technical quality department of the construction unit. Who organizes and who participates? So, you need to grasp this part while also understanding the main body and the project. Now, everyone should understand the unit project completion acceptance procedure. This was our 2017 exam question. The 2011 Level 2 exam had a lot of questions about unit projects. After a unit project meets the completion acceptance conditions... The construction unit must first conduct a self-inspection, then fill out the project completion inspection application form and submit the materials to the project management office. The supervision agency applies for the completion acceptance summary and organizes professional supervision engineering to conduct a pre-acceptance inspection. The chief supervision engineer organizes the construction unit to rectify according to the results of the pre-acceptance inspection. If there are any problems that need to be rectified, the construction unit submits a formal project completion report application to the construction unit after rectification. Article 4: Who submits the completion acceptance report to whom? This is where the construction unit submits the project completion report to the construction unit. Many people get this wrong; it must be submitted to the construction unit, not to the receiving unit. Article 5: After receiving the completion report and application report, the construction unit is responsible for organizing the construction, design, supervision, and exploration projects to conduct the completion acceptance inspection. The construction unit and the five main parties involved are the project exploration and design, construction supervision, and project management. If there is a subcontractor for a unit project, and the inspection is organized according to the procedures and organization specified in the regulations, is it necessary for the subcontractor to participate in the completion acceptance inspection of the unit project? Finally, the general contractor conducts the completion acceptance inspection. These are the procedures for our entire acceptance process. You see, these procedures have been under consideration in recent years, so this is definitely a key area of support, and we hope to draw everyone's attention to them. That's important. Next, let's look at the second point: the acceptance of indoor environmental quality. It's crucial to understand that professional decoration and renovation inherently produce some pollution. Therefore, we need to consider the harmful pollutants from the materials used after the entire renovation is completed. Depending on the control requirements, we'll cover two main building categories: the first includes hospitals, elderly care facilities, kindergartens, and schools, where the requirements for pollutants are very stringent. The remaining categories are called secondary categories, where the restrictions on pollutants are more lenient. Therefore, we must consider hospitals, elderly care facilities, kindergartens, and schools. Moving on, the requirement is that the indoor environmental quality acceptance must be completed within 7 days before delivery for use. This is like a post-mortem examination; the examination must be conducted only after completion. Both conditions must be met before delivery for use. What items need to be tested during the acceptance? All five indicators for the 10-year environmental quality acceptance must be addressed. Organic compounds will always be found; you can write TVOC when answering questions. These are the five indicators we need to test: formaldehyde and ammonia. Now, let's look at the fourth requirement: the total number of tests must be for rooms of the same type.